FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource ValueSet/FHIR Server from package fhir.argonaut.r2#1.0.0 (109 ms)

Package fhir.argonaut.r2
Type ValueSet
Id Id
FHIR Version R2
Source http://fhir.org/guides/argonaut/r2/https://simplifier.net/resolve?scope=fhir.argonaut.r2@1.0.0&canonical=http://fhir.org/guides/argonaut/ValueSet/substance
Url http://fhir.org/guides/argonaut/ValueSet/substance
Version 1.6.0
Status draft
Date 2016-10-18T00:00:00+11:00
Name Argonaut Substance-Reactant for Intolerance and Negation Codes
Experimental True
Realm us
Authority hl7
Description A substance or other type of agent (e.g., sunshine) that may be associated with an intolerance reaction event or a propensity to such an event. These concepts are expected to be at a more general level of abstraction (ingredients versus more specific formulations). This value set is quite general and includes concepts that may never cause an adverse event, particularly the included SNOMED CT concepts. The code system-specific value sets in this grouping value set are intended to provide broad coverage of all kinds of agents, but the expectation for use is that the chosen concept identifier for a substance should be appropriately specific and drawn from the available code systems in the following priority order: NDFRT, then RXNORM, then SNOMED CT. This overarching grouping value set is intended to support identification of drug classes, individual medication ingredients, foods, general substances and environmental entities
Copyright This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement

Resources that use this resource

StructureDefinition
http://fhir.org/guides/argonaut/StructureDefinition/argo-allergyintolerance Argonaut AllergyIntolerance Profile

Resources that this resource uses

CodeSystem
http://snomed.info/sct SNOMED CT (all versions)
http://snomed.info/sct Nutrition Care Process Terminology module
http://snomed.info/sct veri
http://fhir.org/guides/argonaut/ValueSet/substance-ndfrt DAF Substance ND-FRT codes
http://fhir.org/guides/argonaut/ValueSet/substance-rxnorm DAF Substance RxNorm Codes
http://fhir.org/guides/argonaut/ValueSet/substance-sct DAF SNOMED CT Substances Other Than Clinical Drugs


Source

{
  "resourceType" : "ValueSet",
  "id" : "substance",
  "meta" : {
    "lastUpdated" : "2016-05-25T16:59:08.025+10:00"
  },
  "text" : {
    "status" : "generated"
  },
  "url" : "http://fhir.org/guides/argonaut/ValueSet/substance",
  "version" : "1.6.0",
  "name" : "Argonaut Substance-Reactant for Intolerance and Negation Codes",
  "status" : "draft",
  "experimental" : true,
  "publisher" : "Argonaut Project",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "other",
          "value" : "http://argonautwiki.hl7.org",
          "rank" : 0
        }
      ]
    }
  ],
  "date" : "2016-10-18T00:00:00+11:00",
  "description" : "A substance or other type of agent (e.g., sunshine) that may be associated with an intolerance reaction event or a propensity to such an event. These concepts are expected to be at a more general level of abstraction (ingredients versus more specific formulations). This value set is quite general and includes concepts that may never cause an adverse event, particularly the included SNOMED CT concepts. The code system-specific value sets in this grouping value set are intended to provide broad coverage of all kinds of agents, but the expectation for use is that the chosen concept identifier for a substance should be appropriately specific and drawn from the available code systems in the following priority order: NDFRT, then RXNORM, then SNOMED CT. This overarching grouping value set is intended to support identification of drug classes, individual medication ingredients, foods, general substances and environmental entities",
  "immutable" : false,
  "copyright" : "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement",
  "extensible" : false,
  "compose" : {
    "import" : [
      "http://fhir.org/guides/argonaut/ValueSet/substance-ndfrt",
      "http://fhir.org/guides/argonaut/ValueSet/substance-rxnorm",
      "http://fhir.org/guides/argonaut/ValueSet/substance-sct"
    ],
    "include" : [
      null,
      null,
      null,
      {
        "system" : "http://snomed.info/sct",
        "concept" : [
          {
            "code" : "160244002",
            "display" : "No Known Allergies"
          },
          {
            "code" : "429625007",
            "display" : "No Known Food Allergies"
          },
          {
            "code" : "409137002",
            "display" : "No Known Drug Allergies"
          },
          {
            "code" : "428607008",
            "display" : "No Known Environmental Allergy"
          }
        ]
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.